Home > Solved Vista > Solved: Vista Ultimate 64bit Dcom Event Errors

Solved: Vista Ultimate 64bit Dcom Event Errors

The following steps allow that: Launch 'regedit' (as Administrator) Find (Ctrl+F) the following registry key: "{76A64158-CB41-11D1-8B02-00600806D9B6}" (it's in HKEY_CLASSES_ROOT\CLSID) Right click and select 'Permissions' Change owner to administrators group (Advanced...). SP 1 Joeten, have already tried but problem remains. 09-24-2015, 02:25 PM #9 spunk.funk TSF Team, Emeritus Join Date: May 2010 Location: Los Angeles Posts: 36,005 OS: Reply GoodSmith None 0 Points 11 Posts Re: Word automation under asp.net 1.1.4322 & Vista 64-bit Dec 24, 2008 05:04 AM|GoodSmith|LINK

I am still trying to solve this problem myself without This site is completely free -- paid for by advertisers and donations. http://realink.org/solved-vista/solved-vista-64bit-question.html

If you are changing configuration of the jenkins it is possible that slave tries to connect to old masters address. If this bugs you, then upvotehttps://issues.jenkins-ci.org/browse/JENKINS-16061 andhttps://issues.jenkins-ci.org/browse/JENKINS-14559 Windows 2008 R2 (64bit) This is an attempt to describe what I had to do on a clean Windows 2008 R2 (64bit) install to If you're running the x64 version of Windows Server 2008, you'll have to open dcomcnfg.exe directly from c:\Windows\SysWoW64\, because Office isn't 64bit and has to run in WoW mode. Change permissions for administrators group. https://forums.techguy.org/threads/solved-vista-ultimate-64bit-dcom-event-errors.667783/

To turn off NTLMv2 authentication: Run regedit to edit the registry. However, the above solution hasn't finally solved my problems. Slave under domain account If your slave is running under a domain account and you get an error code 0x800703FA, change a group policy: open the group policy editor (gpedit.msc) go I have the time zone correctly set to EST.

Thank you very much! valis replied Mar 7, 2017 at 8:17 AM What Are You Listening to #14 valis replied Mar 7, 2017 at 8:03 AM how to uninstall ubuntu Journee89 replied Mar 7, 2017 SP 1 Spunk.funk, will run SFCFix.exe again and post the results. 09-24-2015, 02:39 PM #12 DavidRen Registered Member Join Date: Sep 2015 Posts: 25 OS: Windows 7 Pro. Similar Threads - Solved Vista Ultimate Vista Control Panel not Accessible Kolias, Feb 21, 2017, in forum: Windows Vista Replies: 7 Views: 149 Kolias Feb 21, 2017 Windows Vista To Go

Reply pk-one None 0 Points 5 Posts Re: Word automation under asp.net 1.1.4322 & Vista 64-bit Jan 06, 2009 04:22 AM|pk-one|LINK Dear GoodSmith, you must be an angel or something Windows will redirect all calls to System32 to SYSWOW64 for 32-bit apps with file system redirection. Follow these steps if you encounter errors during the installation of the Framework: https://stackoverflow.com/questions/14192244/offline-installer-for-net-3-5-sp1-not-working If all else fails... Until I find a way to unify/update the DLLs under Vista 64-bit, I am still hoping someone can provide further useful information - in case my thoughts are irrelevant.

Hope that helps. I can change it manually, but every so often it changes itself ahead. Given that it takes a book (above) to describe how to solve the problem and that some folks have iterated over the book multiple times and still can't get it to Sometimes the generation runs fine, sometimes it fails with a permission problem :( I recently bought the DevExpress components, and changed my .NET projects to use XtraReports instead of generating Excel

ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.2/ Connection to 0.0.0.2 failed. In the console tree, double-clickLocal Policies, and then clickUser Rights Assignment. But all these happened within a couple of second of each other in the time table. Here's my setup Jenkins master:linux Jenkins slave: windows Slave Launch Method: Let jenkins control this windows slaves as as windows service.

Current Temperatures Off to a great start Laptop or charger? http://realink.org/solved-vista/solved-vista-ultimate-ac-power-freeze.html Change owner back to TrustedInstaller (user is "NT Service\TrustedInstaller") Restart Remote Registry Service Installhttp://www.microsoft.com/download/en/details.aspx?displaylang=en&id=5582 on the slave Make sure java is accessible in the PATH. I know that I keep hearing that my 64bit as well as vista tends to have some compatibility issues but they seem to be rare and far between. Perhaps it is IIS 7 or some component of Vista that might be playing foul, such as UAC or something else.

Log in or Sign up Tech Support Guy Home Forums > Operating Systems > Windows Vista > Computer problem? The system returned: (22) Invalid argument The remote host or network may be down. Turning off the DCom Launch service didn't even help and the file was still in use. check my blog Clicking the "Install" button and entering the administrator password led to downloading and installation of the update...except at the end of the process I receive a notice that there were errors

Due to the limitations of 32-bit and 64-bit, you cannot have 32-bit DLLs loading 64-bit DLLs, and the same is true for the other way around. Thank you very much for sharing your solution (most people ask questions and don't share their solution, this is really annoying). With Word 2007, you should have an option in the dcomcnfg, "Word 2007 application" or somethin like that (as you've seen I'm running a german version of windows).

Reply kiranb None 0 Points 17 Posts Re: Word automation under asp.net 2.0 & IIS 6.0 64-bit mode on Win2k3 May 15, 2009 06:34 AM|kiranb|LINK I've the same problem.

SP 1 Have already tried that but problem persists. 09-24-2015, 01:55 PM #7 joeten Microsoft-Team Manager Hardware - Team Manager Join Date: Dec 2008 Location: Glasgow Scotland OR Retrieving the COM class factory for component with CLSID {000209FF-0000-0000-C000-000000000046} failed due to the following error: 8000401a. The communication between Jenkins master and this service happens over a named pipe, which itself is protected by access control. ERROR: Access is denied.

It's possible that something else I changed helped this to succeed, so I'll detail the one additional step which may be necessary. An additional step is necessary, outlined here:http://apache.resourcezen.com/jenkins-slave-authentication Basically, create a directory called 'lib' within the directory where jenkins-slave.exe resides. it working on windows 2003 server. news If you can, do you open word after experiencing an error?

I hope you all had a good holiday. I noticed that my video drivers are also a huge game crasher for me as well and I cannot find anyone that has a solution to that though. This is especially true for Windows Vista, where it is disabled by default. at hudson.remoting.Launcher.parseJnlpArguments(Launcher.java:263) at hudson.remoting.Launcher.run(Launcher.java:190) at hudson.remoting.Launcher.main(Launcher.java:166) Exception in thread "main" java.io.IOException: Failed to validate a server certificate.

Hello, Very nice/usefull error-code page. Jenkins then installs the actual slave as a Windows service, by using the WMI over DCOM, then it starts this service. Access is denied error When you get an "Access is denied. [0x00000005]" error, apply the following patch to the registry: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System create or modify 32-bit DWORD: LocalAccountTokenFilterPolicy set the value to: Solution was found in http://answers.microsoft.com/en-us/windows/forum/windows_7-security/getting-access-is-denied-when-accessing-windows-7/23369f35-bc45-4147-9c3e-74a47d530757 Solution is realy easy just a one key in registry: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System create or modify 32-bit DWORD: LocalAccountTokenFilterPolicy set the value to: 1 Permalink Reply Dec 02,

So I set up a fixed identity and now it seems to work [8-|] Yippie! :D Reply GoodSmith None 0 Points 11 Posts Re: Word automation under asp.net 1.1.4322 & Vista Finally (I almost gave up) I found this post. From the sound of the fix, it seems like Vista 32-bit would have the problem. Remote Registry Service The Remote Registry service must be running in order to install the Jenkins service, but it may be stopped on your computer.

But there should be an entry with the GUID (you should know them if you have done the steps in the registry). No, create an account now.